Poster


P 1 Postoperative Inhaled Nitric Oxide for Adult Valvular Heart Disease
T. Shojima, E. Tayama, N. Hayashida, K. Takagi, M. Amako, S. Aoyagi
Department of Surgery, Kurume University School of Medicine, Japan
 
P 2 Optimization of the Diffuser System for the Integrated Heart Lung Assist Device
T. Tsukiya, E. Tatsumi, T. Nishinaka, N. Katagiri, Y. Takewa, A. Homma, T. Kamimura, Y. Taenaka, H. Takano, S. Kitamura
National Cardiovascular Center, Japan
 
P 3 Postcardiotomy Management for Refractory Pulmonary Hypertension With Systemic Vasodilatory Hypotension
E. Tayama, K. Takagi, T. Shojima, H. Teshima, T. Takaseya, K. Tayama, S. Aoyagi
Department of Surgery, Kurume University School of Medicine
 
P 4 Development of a Cross Flow Blood Pump Designed for All-In-One PCPS System
A. Yoshinaka*, S. Tomizuka*, Y. Asakawa**, I. Taga*, A. Funakubo**, Y. Fukui**
*) The Department of Electronic and Computer Engineering, Graduate School of Tokyo Denki University, Hatoyama, Saitama, Japan
**) The Department of Electronic and Computer Engineering, Tokyo Denki University, Hatoyama, Saitama, Japan
 
P 5 Resonant Frequency Control Method for the Artificial Heart Using Online Parameter Identification
R. Kosaka, Y. Sankai, T. Jikuya*, T. Yamane**, T. Tsutsui
Institute of Eingineering, Mechanics and Systems, *Clinical Medicine, University of Tsukuba, **Aist, Tsukuba, Japan
 
P 6 A Bridge from Short Term LVADs to Long Term LVADs – the Physiological Controller
Y. Wu*, P.E. Allaire*, H.G. Wood*, Y. Liu*, J.M. Adams*, D. B. Olsen**
*) University of Virgina, **) Utah Artificial Heart Center
 
P 7 Hemolytic and Hydrodynamic Performance Analysis of Impeller Design for Centrifugal Blood Pump: Experimental and Computational Evaluation
T. Iida 1), Y. Kawano 2), K. Ohuchi 3), T. Masuda 1), Y. Kimura 2), M. Yoshino 2), N. Watanabe 3), H. Hoshi 3), H. Kataoka 3), T. Yasuda 3), M. Nakamura 3), T. Fujimoto 1), T. Fujita 2), T. Sakamoto 4), S. Takatani 3)
1) Mechanical Engineering, Shibaura Institute of Technology, Tokyo, Japan; 2) Mechanical Engingeering, Nihon University, Tokyo, Japan, 3) Artificial Organs, 4) Thoracic Organ Replacement, Tokyo Medical and Dental University, Tokyo, Japan
 
P 8 Effectiveness of Computational Fluid Dynamic Analysis for the Flow Around the Bearings of Centrifugal Blood Pumps
M. Nishida, Y. Miyamoto, T. Yamane
National Institute of Advanced Industrial Science & Technology, Science University of Tokyo, Japan
 
P 9 Development of Intelligent Wearable Management Server for Implantable Artificial Heart
F. Ichihashi, Y. Sankai, T. Yamane*, T. Jikuya**, T. Tsutsui**
Institute of Engineering Mechanics and Systems, University of Tsukuba, Japan, *) National Institute of Advanced Industrial Science and Technology, Japan, **) Institute of Clinical Medicine, University of Tsukuba, Japan
 
P 10 Hydraulically Levitated Impeller by Controlling Optimum Magnetic Coupling Force for a Clinically Applicable Centrifugal Pump System
S. Tsujimura, S. Ito, K. Watanabe, N. Takano*, T. Asai, A. Hata, J. Glueck, T. Motomura, T. Shinohara**, Y. Sankai***, Y. Nosé
Michael E. DeBakey Department of Surgery, Baylor College of Medicine, USA, *Softronic Co., LTD,. **Miwatec Co. LTD., ***Institute of Engineering Mechanics and Systems, University of Tsukuba, Japan
 
P 11 Centrifugal Blood Pump with Hydraulically Levitated Impeller for the Permanently Implantable Biventricular Assist Device
K. Watanabe, T. Asai, T. Motomura, A. Hata, S. Ito, T. Shinohara, S. Tsujimura, J. Glueck, Y. Nosé
Baylor College of Medicine, Michael E. DeBakey Department of Surgery, Houston, Texas, USA
 
P 12 Real-Time Studies of the Pivot Bearing in the GYRO PI710 Centrifugal Blood Pump
T. Asai*, K. Watanabe*, S. Ito*, S. Tsujimura*, T. Motomura*, A. Hata, T. Shinohara**, J. Glueck*, Y. Nosé*
*) Baylor College of Medicine, Michael E. DeBakey Department of Surgery, USA, **) Miwatec Co. Ltd., Hokkaido, Japan
 
P 13 The ORQIS Medical Cancion Cardiac Recovery Systems (CRS) – Clinical Experience at the Jagiellonian University; Krakow, Poland
J. Sadowski, B. Kapelak, K. Bartus, R. Dwila, P. Przybylowski, Z. Samitowski
Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, Krakow, Poland
 
P 14 Pulsatile Extracorporeal Life Support May Provide Versatility in Optimizing Cardiac and Circulatory Support
L. Sauren*, K. Reesink*, A. Dekker*, T. van der Nagel*, E. Severdija*, C. Soemers*, G. Geskes*, J. Maessen*, E. van der Veen*
*) Cardiothoracic Surgery, Cardiovascular Research Institue Maastricht, Maastricht, The Netherlands
 
P 15 Magnetically Suspended Centrifugal Blood Pump with Novel Axially Levitated Motor
H. Onuma, T. Masuzawa, M. Murakami, Y. Okada
Ibaraki University, Ibaraki, Japan
 
P 16 Durabilty and Animal Testing of an Implantable Microdiagonal Pump
M. Akdis; M. Martin., R. Autschbach*, S. Christiansen*, L. Demircan*, P. Kwant, H. Reul
Institute for Biomedical Technologies (IBMT), RWTH Aachen, Germany
* Clinic for Cardiothoracic Surgery, University Clinic Aachen, Germany
 
P 17 Construction of the Ventricular Assist Device With the Technology of the Undulation Pump Total Artificial Heart
Y. Abe*, T. Chinzei*, T. Isoyama*, S. Mochiduki*, I. Saito*, T. Ono*, K. Iwasaki**, K. Takiura*, A. Kouno*, K. Imachi*
*) The University of Tokyo, Tokyo, Japan.
**) Waseda University, Tokyo, Japan
 
P 18 Component Engineering for the Implantable Ventricular Assist System
T. Yambe*, Y. Shiraishi*, M. Esashi*, Y. Haga*, M. Yoshizawa*, F. Sato*, M. Yoshizawa*, K. Imachi**, Y. Abe**, S. Nitta
*) Tohoku University, **) the University of Tokyo
 
P 19 Assessment of a Pulse Induced by Modulating the Speed of a Continuous-Flow Rotary LVAD
K. Bourque*, D. Cassidy*, C. Dague*, H. Loree*, V. Poirier*, D. Farrar*, T. Gempp+, V. Steinacher+, R. Schöb+
* Thoratec Corporation, Woburn, MA, USA; + Levitronix, GmbH, Zürich, Switzerland